Back to Forums
2 posts / 0 new
Last post
#1 Aug 17, 2017
Sbrettsc
Offline
Last seen: 3 years 9 months ago
Joined: 2017-08-17 21:19

Batch simulations with 1 circuit file

I'm running a batch simulation by adding multiple simulation profiles to the same circuit file.  The purpose of the batch simulation was to take the same netlist but vary the circuit models and simulate it all at once.  It simulates OK, and after it completes PSpice asks me which sections to plot, similarly to how it works for Monto Carlo simulations.  However, once the traces are plotted I have no way of knowing which trace came from which simulation (the net names are the same between simulations, only circuit models were changed).  If I click on the net and choose "trace information" it doesn't give any indication what simulation it came from.  is there anyway to view this information after the traces are plotted?

Thu, 2017-08-17 23:07
alok
Offline
Last seen: 1 year 3 weeks ago
Joined: 2016-05-10 23:49

if each of these simulations results are coming from different (or independednt cir file) there is no direct way to identify the cir file from trace info dialog - Only option I can think of is to count the order of trace and then corelate to specific cir file.

if you are running sweep analysis - you can find sweep variable name in trace information dialog. 