4 posts / 0 new
Last post
#1 Jul 10, 2018
ras
Offline
Last seen: 5 days 22 min ago
Joined: 2018-07-10 02:18

A small design but EVALUATION VERSION Limit Exceeded for "Q" Devices!

Hi,

Only one Op-Amp in my design, still I can't run the pspice lite, is it really reached its limit?

 

** WARNING: THIS AUTOMATICALLY GENERATED FILE MAY BE OVERWRITTEN BY SUBSEQUENT SIMULATIONS

*Libraries: 
* Profile Libraries :
* Local Libraries :
* From [PSPICE NETLIST] section of C:\Users\43497519\cdssetup\OrCAD_PSpice\17.2.0\PSpice.ini file:
.lib "C:\Cadence\SPB_17.2\tools\pspice\library\nom.lib" 
.lib "nomd.lib" 

*Analysis directives: 
.TRAN  0 100ms 0 
.OPTIONS ADVCONV
.PROBE64 V(alias(*)) I(alias(*)) W(alias(*)) D(alias(*)) NOISE(alias(*)) 
.INC "..\SCHEMATIC1.net" 

**** INCLUDING SCHEMATIC1.net ****
* source OPTOSCANAMP
R_R1         N00240 9V  1k TC=0,0 
R_R2         0 N00240  1k TC=0,0 
C_C1         0 N00240  1n  TC=0,0 
C_C2         N00240 0  1n  
R_R3         0 N00457  100k TC=0,0 
R_R4         N00457 N00542  47k TC=0,0 
V_V1         N00542 N00240  
+SIN 0V 100mV 100Hz 0 0 0
X_U1         N00240 N00542 0 N00457 9V OPA650X/BB

**** RESUMING LevelShifter.cir ****
.END

ERROR -- Circuit Too Large!
EVALUATION VERSION Limit Exceeded for "Q" Devices!

Tue, 2018-07-10 03:15
oldmouldy
Offline
Last seen: 3 days 18 hours ago
Joined: 2016-07-06 04:23

Because the op-amp has more than 20 transistors ("Q" devices) in it, the limit for the Lite version is exceeded.

Tue, 2018-07-10 03:37
ras
Offline
Last seen: 5 days 22 min ago
Joined: 2018-07-10 02:18

Is it simulating each transistor inside the Op-Amp separately? And I didn't see the transistor count in the Op-Amp datasheet!

Sun, 2018-07-15 19:33
retiredEE
Offline
Last seen: 6 hours 40 min ago
Joined: 2018-03-21 12:19

Open the library burr_brn with the PSpice model library editor.  Select your model (OPA650X/BB) and view the text of the model.  There are 25 transistors in this op amp model.

Download PSpice Lite and try it for free! Get PSpice Lite