Ive been trying to run an AC sweep on a basic circuit. I get an error stating ERROR(ORPSIM-16103): Invalid value

Location

India
IN


**** 06/18/22 22:01:49 ****** PSpice Lite (October 2012) ****** ID# 10813 ****

 ** Profile: "SCHEMATIC1-output"  [ D:\PSPICE\PSPICE PROJECTS\EmitterFollowe-PSpiceFiles\SCHEMATIC1\output.sim ] 


 ****     CIRCUIT DESCRIPTION


******************************************************************************


** Creating circuit file "output.cir" 
** WARNING: THIS AUTOMATICALLY GENERATED FILE MAY BE OVERWRITTEN BY SUBSEQUENT SIMULATIONS

*Libraries: 
* Profile Libraries :
* Local Libraries :
* From [PSPICE NETLIST] section of C:\SPB_Data\cdssetup\OrCAD_PSpice/16.6.0/PSpice.ini file:
.lib "nomd.lib" 

*Analysis directives: 
.AC DEC 10 100 100m
---------------$
ERROR(ORPSIM-16103): Invalid value
.OPTIONS ADVCONV
.PROBE64 V(alias(*)) I(alias(*)) W(alias(*)) D(alias(*)) NOISE(alias(*)) 
.INC "..\SCHEMATIC1.net" 

**** INCLUDING SCHEMATIC1.net ****
* source EMITTERFOLLOWE
V_V3         IN 0 DC 0Vdc AC 1Vac 
C_C4         0 OUT  1n  TC=0,0 
R_R7         0 OUT  1k TC=0,0 
R_R6         IN OUT  1k TC=0,0 

**** RESUMING output.cir ****
.END

 

 

Sun, 2022-06-19 11:04
retiredEE
Offline
Last seen: 1 week 4 days ago
Joined: 2018-03-21 12:19

Your end frequency (100m) is less than the start frequency (100).  My guess is you want the end frequency to be 100Mhz so specify it as 100MEG.

Sun, 2022-06-19 11:43
girishrwb
Offline
Last seen: 1 week 4 days ago
Joined: 2022-06-18 12:34

thank u soo much retiredEE !!!