system is giving always final values of C or L

sir/mam,

my Pspice system is always giving final values of Capacitor or Inductor in the circuit from t=0 (when i am doing transient analysis) even when i am not imposing any initial condition,

so how can i make it normal??

with thanks

Sun, 2017-08-27 08:23
alok
Offline
Last seen: 1 year 1 month ago
Joined: 2016-05-10 23:49

IC on capacitor or Inductor should serve the need. Or You can use SKIPBP in .tran command. 

 

* RC Charging
V1 1 0 10
R1 1 2 1
C1 2 0 1m 
.probe64
.tran 1u 1m 0 0 SKIPBP
.end
 

 

Or

 

* RC Charging
V1 1 0 10
R1 1 2 1
C1 2 0 1m ic=0.01
.probe64
.tran 1u 1m 0 0

.end
 

Both of these should show - capacitor voltage charging. Is this what you are looking for?