Dear support team,
I have a problem with IBIS model importing into PSpice. I have a model of DS90LV804 downloaded from the TI page. When I try to import the IBIS model, it writes an error: Errors during IBIS parsing. Please see ibis2pspice.log for details. The ibis2pspice.log is empty. I also tried to use another IBIS to spice converters but I was not successful. Can you please recommend me how to use this IBIS model in PSpice?
You can see the screenshot here.
Best regards,
Marta
Copyright © 2020 Cadence Design Systems, Inc. All rights reserved.
If somebody will have the same problem, there is the solution which worked for me:
After the error occurs, the new file ds90lv804.dml.txt is created at the same folder. When the extension of the created file is changed just to *.dml (delete the the txt), the dml file can be opened with the converter. It is necessary to check the "Create macro-models by Signal Names", otherwise there is an error during the simulation.
I hope it is a correct way, because it was the only working way.