sir/mam,
my Pspice system is always giving final values of Capacitor or Inductor in the circuit from t=0 (when i am doing transient analysis) even when i am not imposing any initial condition,
so how can i make it normal??
with thanks
Copyright © 2020 Cadence Design Systems, Inc. All rights reserved.
IC on capacitor or Inductor should serve the need. Or You can use SKIPBP in .tran command.
* RC Charging
V1 1 0 10
R1 1 2 1
C1 2 0 1m
.probe64
.tran 1u 1m 0 0 SKIPBP
.end
Or
* RC Charging
V1 1 0 10
R1 1 2 1
C1 2 0 1m ic=0.01
.probe64
.tran 1u 1m 0 0
.end
Both of these should show - capacitor voltage charging. Is this what you are looking for?