Hi,
I have a problem with the simulation settings. I have added PSpice models from the Internet into my schematic and after creating a simulation profile I added under configuration files all my .lib files. Everytime I start a new Simulation one of my .lib files has to be added again. But all the other files stay attached to the simulation profile.
Does anyone know, what the reason for this problem could be and how I could solve it?
Thanks
Miriam
Copyright © 2020 Cadence Design Systems, Inc. All rights reserved.
Hello Miriam,
Could you tell me how many .libs are you trying to add and if you do it as Global, Design or Profile?
Which Version and Hotifx do you use?
Regards
Hi Roberto,
I am currently using 6 internet models (6 .lib files). I added all of them one after one, as I am building my schematic as Add to Profile.
For example I added the diode GSOT12C.lib --> .\GSOT12C.lib
Thanks
Miriam
Hello,
I have tried, but I cannot reproduce the error. So I have added 8 library to a Simulation Profile as "Profile", I have simulated and the libraries are still in the simulation profile. I am using Version 17.2 and Hotfix 24. and you?
Hello Roberto,
I am using Version 17.2-2016. The .lib file that is deleted everytime is the Diode STTH1212D from the ST website. I downloaded the zip file with the .olb and the .lib file included.
It works fine until I start changing for example the run time of the simulation, or add another new model.
ST_ULTRAFAST_800V_1000V_1200V_V5.lib
Maybe this information helps.
Thanks,
Miriam
Hi Miriam,
Yes, I can reproduce the issue. And it has to do with the library you mentioned. Morover, it happens only when you define the library as Add to Profile. If you do it as "Add to Design" this issues does not happen.
I will try to find out why this is happening.
Regards
Many Thanks!